Assembling a coaxial cable connector with tools

Engineering guide

Feeder length and the art of a quality connector

A 20-meter run of thin cable can dissipate half the amplifier's output before it reaches the antenna. Cable length is a design choice, and most signal loss occurs at the connections on either end.

Length and termination are included in one budget.

Cable loss isn't a footnote in jammer installations—it directly reduces the effective signal at the handset. Doubling the distance requires 6 dB more power, so losing 3 dB in the feeder shrinks the usable range by roughly 30%—often enough to turn a fully covered hall into one that's only half-covered.

A practical target is to keep the total feeder path loss—spanning jumpers, connectors, and the main run—below 3 dB across the highest operating band. This is easily achievable at 900 MHz with a thick cable but nearly impossible at 3.5 GHz with a thin one, which is why the band plan and cable plan must be developed together.

The loss figures by band and connector type are detailed in the RF cable and connector loss guide. This article covers selecting the run and assembling the ends.

Typical cable loss per meter

Cable Type900 MHz2.1 GHz3.5 GHzWhere it belongs
RG58 / RG316 (thin)0.55dB/m0.95dB/m1.25dB/mShort jumpers and test leads stored in an enclosure, under 1 m
RG142 / LMR195 class0.30dB/m0.55dB/m0.72dB/mCabinet-to-antenna runs up to 5 m; handhelds with external antennas
LMR400 / 1/4-inch class0.13dB/m0.23dB/m0.30dB/mWall-to-antenna runs of 10 – 20 m
1/2-inch foam (Heliax)0.07dB/m0.13dB/m0.17dB/mMast runs of 20 – 50 m; rooftop installations

Typical values for planning. Refer to the datasheet for the exact cable and add 0.1 – 0.3 dB per connector pair.

A calculated budget at 2.1 GHz

  • Amplifier output (per band)43 dBm (20 W)
  • Jumper + main feeder (−3 dB)40 dBm at the antenna port
  • Antenna gain (+10 dBi)50 dBm EIRP
  • Path loss to the far edge (80 dB)-30 dBm at the handset
  • Ambient cell signal at that point-85 dBm typical indoors
  • Jamming margin55 dB — comfortable

Replace the 3 dB feeder with a 7 dB one, and the margin at the far edge drops to 51 dB — still viable in strong-signal areas, but marginal near a macro site.

Six steps to a lasting joint

1. Cut the square and strip to match the connector drawing.

Use the strip dimensions from the connector datasheet, not an estimate. The dielectric must be cleanly cut and the braid intact. A strip that is 1 mm long exposes the center conductor inside the connector body, creating a short risk when the coupling nut is tightened.

2. Keep braid strands away from the dielectric.

A single stray strand touching the center pin creates a DC short and RF reflection. Inspect with a light before assembly; once the connector is crimped, the only fix is replacing it and trimming 30 mm from the cable.

3. Adjust the center-pin protrusion to match the drawing.

For N and SMA connectors, the pin must be positioned at a specified height above the mating face—typically 0.5 to 1 mm depending on the series. Recessed pins cause intermittent contact; protruding pins can damage the mating connector. Verify using the gauge in the assembly kit.

4. Crimp or solder once to the rated force.

Use the correct die for the cable and connector combination. A loose crimp acts as a resistor; an over-crimped one crushes the dielectric. Ensure solder joints have a clean, tinned surface with no excess solder inside the body. Do not re-crimp a failed joint—cut it off and start over.

5. Torque couplings to spec; do not use adapters.

Specify N connectors around 1.4 – 1.8 N·m. Tighten SMA by hand plus a slight pinch; do not use a wrench. Each adapter adds 0.1 – 0.3 dB and introduces a mechanical joint that may loosen. If an adapter is unavoidable, secure it with tape and log the connection.

6. Weatherproof and strain-relieved

Wrap the self-amalgamating tape over the joint, starting from the cable and extending onto the connector body. Overlap each layer by 50%, then create a drip loop to ensure water drains away before reaching the seal. Support the cable every 50–80 cm on outdoor runs to prevent the connector from bearing any weight.

Parts to specify

Three accessories eliminate most improvisation. The 50-9 ultra-flexible RF cable with dual N male connectors covers cabinet-to-antenna runs inside a building; the RG316 SMA jumper Designed for short test and panel connections, as well as N female to SMA male adapter Bridges the two series when an antenna and a module are incompatible.

For testing, a 200 W dummy load Allows you to measure forward power into a known 50 Ω termination before connecting the antenna. Compare this value with the reading taken after installing the feeder: the difference represents the actual loss you installed, not the datasheet loss.

Issues that arise months later

Output drops a few dB one month after installation

Water present in the connector. The seal was applied over a damp joint or with a gap at the bottom of the drip loop. Cut back 100 mm, dry, re-terminate and re-tape, then re-test VSWR, as corrosion often remains inside the connector body.

High VSWR on a single band

A connector or cable may fail at a specific frequency, or a 75 Ω component may be mismatched in a 50 Ω system. Test the cable alone with a known load before suspecting the antenna.

Signal loss when the door or mast moves

A cable tie crushing the dielectric, or a connector that wasn't fully seated. Gently flex the run while monitoring the meter; the point where the reading jumps indicates the fault.

Center pin pushed back into the connector

Over-tightening or a mismatched mating connector. The pin is no longer at the reference plane, resulting in marginal contact. Replace the connector; re-pinning a damaged one rarely maintains its dimensions.

Record as-built run data: cable type, length, connector types, VSWR sweep results, and forward power at the antenna port. When coverage issues arise, this data helps isolate cable vs. radio problems in about five minutes.

Outdoor feeder installation must remain within the authorized coverage boundary. Elevated runs, mast work, and work near live antennas require proper safe-work procedures—not just the correct crimping tool.

Frequently asked questions

What is the maximum length for a jammer antenna cable?

Cable length is determined by the loss you can tolerate, not a fixed maximum. With 3 dB of budget, LMR400-class cable reaches approximately 20 m at 900 MHz and 13 m at 2.1 GHz; 1/2 inch foam cable reaches about 40 m and 23 m on the same bands. Calculate your budget first, then select the cable.

Does a longer cable reduce the jamming range?

Yes, it's directly proportional to the loss. Every 6 dB of loss halves the usable distance in a clear line-of-sight path, so 3 dB of extra cable reduces the radius by approximately 30%. That's why the run is designed with the antenna position in mind, not decided after installation.

Can I connect two cables using a barrel adapter?

You can, but each joint costs 0.1 – 0.3 dB and introduces a mechanical failure point vulnerable to water and vibration. When extending a run, use a single length of the next larger cable size or a properly sealed bulkhead feed-through on both sides.

What VSWR should I expect after termination?

A properly installed cable and antenna should show a VSWR below 1.5:1 across the operating band. A rise in VSWR at one end of the band typically points to a connector issue or excessive cable loss at that frequency, not an antenna fault.

How do I test a cable without a network analyzer?

Use a directional power meter with a known load, or measure forward power into a dummy load at both ends of the run and compare. Many site kits include a compact VSWR meter; sweeping the band and recording the curve provides more insight than a single reading.

Should connectors be soldered or crimped?

Crimped connectors offer greater production consistency and easier inspection; soldered center pins are common in N-type assemblies for higher power applications. The key is to follow the connector assembly drawing and use the matching die or solder specification. Signal loss occurs when using mixed or improvised assemblies.

Planning a feeder run?

Enter the distance, frequency bands, and antenna position. We'll provide the cable category, maximum length, and connector list for your run.

For authorized agencies only. Verify permissions, frequency assignment, and operator training before deployment.

Contact via WhatsApp