Measuring...

Measured test data for the 2.4 GHz 100 W module

Two bench studies are underway: DC-to-RF efficiency with case temperature rise, and VSWR protection stage response to open and short antenna conditions. Each report will include the captured trace, test conditions, and instrument list so results can be verified rather than assumed.

No values are displayed until measured. For current factory test records for a specific model, please request them with a quotation.

Efficiency and Temperature Rise

BCSK-W100, 2400–2500 MHz, continuous wave; bench ambient recorded per run.

Output power at 2400 MHz
Pending

Power meter at antenna port, cable loss corrected

DC input power
Pending

Supply voltage and current logged at module terminals

DC-to-RF efficiency
Pending

Calculated at 25, 50, 75 and 100% of rated drive

Case temperature rise
Pending

Thermocouple on the heatsink base, 25 °C ambient temperature, no forced air

Heatsink thermal resistance
Pending

Derived from dissipation and measured rise

VSWR protection response

Connect BCSK-W100 to an open and short load, then capture forward and reflected power on a scope.

Forward and reflected power
Pending

Dual directional coupler connected to an oscilloscope; logging data before and after the trip.

Trip threshold
Pending

Reflected power threshold at which the protection stage reduces gain

Response time
Pending

Time from fault to reduced output, read from captured trace

Recovery Behavior
Pending

Resume rated output after mismatch is resolved

Repeated Fault Tolerance
Pending

Ten consecutive open and short cycles; output recorded for each cycle.

How measurements are taken

Instruments
Power meter, bidirectional coupler, DC power supply with current logging, oscilloscope, calibrated thermocouple
Terms
Bench ambient temperature recorded per run; continuous wave drive unless stated, 50 Ω load except during fault tests
Repeatability
Each condition measured three times; spread reported with results.
Release policy
Figures are displayed only with the captured trace and instrument list; untested values remain hidden.

Questions about the data

When will the measured results be published?

Two studies are being logged on the bench. Each page goes live with its captured traces, test conditions, and instrument list attached—no estimates included.

Can I access test data before it is published?

View factory test records for a specific module, including the quoted model and parameters.

Why publish raw traces instead of a summary table?

A trace reveals transient behavior hidden in summaries, such as how quickly the protection stage responds and whether the output recovers cleanly. Buyers can compare this against their own protection requirements.

Need current test records for a specific model before study publication?

Contact via WhatsApp